Two 37 kW screw air compressors can sit side by side on a factory floor, wear the same motor badge, and still deliver different amounts of air. One pushes out 5.6 m³/min at 8 bar while the other manages 5.1 m³/min — an 8% gap that quietly becomes thousands of dollars of extra electricity every year. That difference is what screw air compressor FAD is meant to expose, and it is the single number most buyers skip when they compare quotations.
FAD, or free air delivery, is the volume of air the compressor actually discharges at its rated working pressure, corrected to standard inlet conditions. It is the only output number that matters for your tools and your process. Rated power tells you what the motor can consume. FAD tells you what you actually get.
What FAD Actually Measures
Free air delivery is quoted in m³/min or CFM at a defined inlet condition, usually 20°C, 1 bar absolute, and 0% relative humidity. It is measured at the discharge of the package, after the airend, motor, cooling, and filtration losses have already happened. A 37 kW badge is motor input power, not air output, and a badly matched airend can burn several percent of that power as heat before a single cubic meter reaches your pipe.
This is why two machines with identical kW ratings can differ by 5–10% in real output. The fairest way to compare them is specific power: kW of input divided by m³/min of FAD. Lower is better, because every kW/m³/min you shave goes straight off the electricity bill.
Three Numbers to Check Before You Buy
Ask every shortlisted supplier for these three figures on one sheet, at the same pressure and the same inlet conditions:
- FAD in m³/min at your required working pressure — for example 8 bar — not at a lower, flattering pressure.
- Specific power in kW/m³/min at that same pressure, taken from the CAGI or type-test data sheet.
- The ambient temperature the machine is rated for. A unit designed for 40°C derates badly in a hot plant, while one engineered for 52°C holds output where others trip.
Real Numbers: Single-Stage vs Two-Stage Specific Power
The gap between a standard single-stage and a two-stage screw air compressor is concrete. In Panrui comparison data, a 22 kW single-stage unit runs about 7.6 kW/m³/min, while a two-stage of the same power runs about 6.8 kW/m³/min. At 90 kW the spread widens further: roughly 7.0 kW/m³/min for single-stage against 5.9 kW/m³/min for two-stage.
- 22 kW: 7.6 single-stage vs 6.8 two-stage
- 37 kW: 7.3 vs 6.5
- 55 kW: 8.0 vs 6.5 horizontal two-stage
- 75 kW: 7.0 vs 6.2
- 90 kW: 7.0 vs 5.9
That difference is not cosmetic. A two-stage machine can be around 15% more efficient than a single-stage because it splits compression into two steps, keeping the process closer to isothermal compression. Over 8,000 running hours a year, even a 1.0 kW/m³/min improvement on a 90 kW machine is worth thousands of dollars in power.
Why One Extra Bar Costs 8% of Your Power
FAD only means something at a stated pressure, and compressing to a higher pressure than your process needs is the most expensive mistake in a compressed air system. Every 1 bar of overpressure adds roughly 8% to energy consumption. If your valves and tools need 6 bar and the compressor is set to 7.5 bar, you are paying for air you never use.
Check the setpoint before you check anything else. A variable-speed screw air compressor holds a steady pressure band and removes overpressure waste, which is why it is often the fastest energy win on a fixed-speed machine.
What Buyers Get Wrong About Free Air Delivery
- Comparing FAD at different pressures. Always compare at the same bar.
- Treating motor kW as air output. kW is input; FAD is output.
- Ignoring inlet conditions. Hot, humid, or high-altitude intake air reduces real FAD.
- Buying on price per kW instead of price per m³/min of FAD.
Your Next Step
Before you sign, put FAD and specific power on the same line of your comparison table. Ask for the type-test sheet, then confirm the warranty covers the airend and the drive for at least two years, and five years on two-stage machines from 55 kW up. Start with our rotary screw air compressor guide for the full sizing picture, or review the two-stage screw air compressor data to see specific power numbers for your model.