How to adjust the data after you do the maintenence?
Change the time data for the used and unused oil and filters every time when you do the maintenance. Filters Set, Lubricate Water Set, Grease Set change into 2000 H, Filters Used, Lubricate
How to do the maintenance for the screw compressor?
Oil brand: Shell or Mobil ISO 46, synthetic compressor oil. After replace the filters, need to adjust the data for the oil and filters. If you don’t know how, please contact info@prcom
How to connect the wires of the compressor and dryer?
For the 3 phases compressor usually needs to be connected with the 3 live wires and 1 ground wire. Some compressors also need to be connected with the neutral wire. If the compressor alarms